 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
NEW
Miniature Waterproof Shielded Connectors
LF Series
Mated dimensions
8.9 mm max. (3 pos.) 36.4
Receptacle
Plug
Short turn bayonet lock
Mating: Insert the plug, and then turn the locking collar clockwise, as indicated by the coupling direction marking.
Features
1. Ease of shielded termination and connector assembly
All components are self-aligning and do not require complex assembly tooling. The shield of the cable is connected with the metal housing of the connector using simple shielding clamp, supplied with the connector.
Receptacle Locking collar Coupling direction marking Plug
Un-mating: Turn the locking collar counter-clockwise than pull off the plug.
2. Water and dust protected
IP67 protection rating. Complete protection against dust penetration and against water penetration when mated assembly is submerged at the depth of 1.8 meter for 48 hours.
Coupling direction marking
3. Bayonet lock
Short turn bayonet lock assures secure vibration resistant mating of the connectors.
Shielding Connection - Plug
4. High current rating capacity
Number of contacts 3 4 6, 12 and 20 11 Current rating 5A max. 10A max. 2A max. 10A max. 2A max.
Built-in shield connection spring
Cable shielding connection clamp Cable
5. RoHS compliant
All components and materials comply with the requirements of the EU Directive 2002/95/EC.
Applications
Sensors, robots, injection molding machines, NC, factory automation equipment, surveying instruments, measuring instruments, medical equipment, surveillance cameras and base stations. 2008.5
O13
1
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF SeriesMiniature Waterproof Shielded Connectors
Product Specifications
Voltage rating 125V AC, 175V DC (3 pos.) 125V AC, 125V DC (4 pos.) 30V AC, 42V DC (6 pos. , 12pos. , 20pos.) 125V AC, DC (11 pos. A to D) 30V AC, 42V DC (11 pos. 1 to 7) 5A max. (3 pos.) 10A max. (4 pos.) 2A max. (6 pos. , 12pos. , 20pos.) 10A(11 pos. A to D), 2A(11 pos. 1 to 7) -25c to +85c (Note 1) -25c to +85c (Note 2)
Rating
Current rating Operating temperature range Storage temperature range
Item
11.Contact resistance
Specification
15 mo max. (3, 6, 12, 20 pos.) 15 mo max. (4 pos.) 15 mo max. (A to D), 15mo max. (1 to 7)(11 pos.) 1000 Mo min. 1A DC
Conditions
12.Insulation resistance
13.Withstanding voltage
No flashover or insulation breakdown.
500V DC (3, 4 pos.) 100V DC (6, 12, 20 pos.) 500V DC (A to D), 100V DC (1 to 7)(11pos.) 1250V AC/one minute (3, 4 pos.) 300V AC/one minute (6, 12, 20 pos.) 1250V AC(A to D),300V AC(1 to 7) / one minute(11pos.) Frequency: 10 to 500Hz, single amplitude of 0.75mm, acceleration of 98 m/s2 for 3 hours in 3 axis. Acceleration of 490m/s2, 11ms duration, sine half-wave waveform, 3 cycles in each of the 3 axis. 1000 cycles Temperature: -55c Room temperature +125c Room temperature Time: 30 10 to 15 30 10 to 15 (minutes) 5 cycles 96 hours at temperature of 40c and humidity of 90% to 95%. Complete dust protection. No water penetration when submerged for 48 hours at the depth of 1.8 meter.
14.Vibration
No electrical discontinuity for 10s max.
15.Shock 16.Durability 16.(Mating/un-mating) 17.Temperature cycle
No electrical discontinuity for 10s max. 30 mo max. (3, 6, 12, 20 pos.) 10 mo max. (4 pos.) 10 mo max.(A to D), 30 mo max.(1 to 7)(11pos.) Insulation resistance: 100 Mo min. Insulation resistance: 110 Mo min. (When temperature high) Insulation resistance: 100 Mo min. (Dray state) When mated with corresponding connector.
18.Humidity
19.Water / dust protection
Note 1: Includes temperature rise caused by the current flow. Note 2: The term "storage" refers to products stored for long period of time prior to mounting and use. Operating temperature range and humidity range covers non-conducting condition of installed connectors in storage, shipment or during transportation.
Materials / Finish
Components
Body / back shell Insulator Contacts Gasket
Material
Zinc alloy PPS Copper alloy Chloroprene rubber
Finish / Color
Nickel plated Black Gold plated Black
Remarks
----------
UL94V-0
---------- ----------
Ordering Information
1 Series name 2 Shell size
: LF 07 10 13 W : Waterproof type B : Bayonet lock P : Plug R : Receptacle J : Jack : 3, 4, 6, 11, 12, 20 P : Male contact S : Female contact
LF 07 - W B P - 6 S
1 2 3 4 5 6 7
3 Waterproof 4 Lock Mechanism 5 Connector type
6 Number of contacts 7 Contact type
2
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF SeriesMiniature Waterproof Shielded Connectors
Plugs
B (Cable dia.)
OA
(Shown one example)
Unit:mm
Part number
LF07WBP-3S LF07WBP-3P LF07WBP-6S LF07WBP-6P LF10WBP-4S LF10WBP-4P LF10WBP-12S LF10WBP-12P LF13WBP-20S LF13WBP-20P LF13WBP-11S LF13WBP-11P
CL No.
136-0003-7 136-0004-0 136-0001-1 136-0002-4 136-0005-2 136-0006-5 136-0007-8 136-0008-0 136-0009-3 136-0010-2 136-0011-5 136-0012-8
Contact
Female Male Female Male Female Male Female Male Female Male Female Male
Number of contacts
3
OA
B
OC
Weight RoHS
12.3 6 4 14.8 12 20 17.9 11
35.3
5
11g
41.8
7.3
17g
YES
51.9
8.7
29g
Receptacles
C D
OB OA
F(HEX)
E
(Shown one example)
Unit:mm
Part number
LF07WBR-3P LF07WBR-3S LF07WBR-6P LF07WBR-6S LF10WBR-4P LF10WBR-4S LF10WBR-12P LF10WBR-12S LF13WBR-20P LF13WBR-20S LF13WBR-11P LF13WBR-11S
CL No.
136-1003-2 136-1004-5 136-1001-7 136-1002-0 136-1005-8 136-1006-0 136-1007-3 136-1008-6 136-1009-9 136-1010-8 136-1011-0 136-1012-3
Contact
Male Female Male Female Male Female Male Female Male Female Male Female
Number of contacts
3
OA
OB
OC C
15.15
D
E
F
Weight RoHS
10.3 6 4 12.8 12 20
13
15.05 15.25 19.05
7.65
1M90.75
11
4g
6g 7.75 M110.75 13 5g 6g 9g 10g 9g 10g YES
15.3 17.25
15.9
11
18.3
19.05
7.75
M140.75
17
Note: Recommended hex nut tightening torque: 1.5 to 2 N*m (3,4,6, and 12 pos.), 2 to 2.5 N*m (11, 20 pos.)
OC
3
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF SeriesMiniature Waterproof Shielded Connectors
Jacks
C
OB OA
(Shown one example)
Unit:mm
Part number
LF07WBJ-3P LF07WBJ-3S LF07WBJ-6P LF07WBJ-6S LF10WBJ-4P LF10WBJ-4S LF10WBJ-12P LF10WBJ-12S LF13WBJ-20P LF13WBJ-20S LF13WBJ-11P LF13WBJ-11S
CL No.
136-2003-8 136-2004-0 136-2001-2 136-2002-5 136-2005-3 136-2006-6 136-2007-9 136-2008-1 136-2009-4 136-2010-3 136-2011-6 136-2012-9
Contact
Male Female Male Female Male Female Male Female Male Female Male Female
Number of contacts
3
OA
OB
C
OD
Weight RoHS
10.3 6
11.5
36.3
5.0
11g
4 12.8 12 29g 15.9 11 16.9 52.4 8.7 30g 29g 30g 13.8 42.4 7.3 16g YES
20
4
OD (Cable dia.)
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF SeriesMiniature Waterproof Shielded Connectors
Applicable tools
Unit:mm
Description
Manual cable clamp crimp
Part number
LF-TC-01
CL No.
150-0234-6
LF series Applicable cable dia.
5 (Note) 7.3 * 8.7
HR10A-TC-02 150-0041-2
Solder termination fixture
Note: Applicable cable dia. is only 5mm for LF series.
Part number
LF07BP-T01 LF07BJ-T01 LF10BP-T01 LF10BJ-T01 LF13BP-T01 LF13BJ-T01
CL No.
150-0232-0 150-0233-3 150-0235-9 150-0236-1 150-0237-4 150-0238-7
Applicable connectors
LF07WBP-6S,6P,3S,3P LF07WBJ-6S,6P,3S,3P LF10WBP-4S,4P,12S,12P LF10WBJ-4S,4P,12S,12P LF13WBP-20S,20P,11S,11P LF13WBJ-20S,20P,11S,11P
Panel Cutout
Alignment guide
Contact position arrangement and specifications
Shell size LF07 LF10
9 1 10 2 A
1 5 2 6 3 7
A
5 .0 +0 0
unit (mm) Shell size LF07 LF10
B
+0.05 0
A O9.05 O11.05 O14.05
B 8.1 10.2 13.1
Panel thickness 0.5 to 2 0.7 to 2 0.7 to 2
LF13
LF13
1
Contact configuration
3 2
1
6 5 4
1 2 3
4 3
1 2
8
B
C D
4 6
2 7
3 8
4
5 9 10
7 12 11 3 6 54
11 12 13 14 15 16 17 18 19 20
Number of contacts Withstanding voltage Current rating Insulation resistance Contact resistance Solder pot inner diameter
3 1250V AC 5A 1000Mo 15mo 1.15mm
6 300V AC 2A
4 1250V AC 10A 1000Mo 5mo
12 300V AC 2A 1000Mo 15mo 0.8mm
4 AC1250V 4 10A
11
7 AC300V 7 2A
20 AC300V 2A 1000Mo 4mo 0.8mm
1000Mo
4 5mo 4 O1.7 7 15mo 7 O0.8
0.8mm
1.7mm
Note 1: The contact configuration as viewed from the female contact connector mating side. Note 2: The symbol indicates polarizing key position. Note 3: Withstanding voltages are test voltage values.
5
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF SeriesMiniature Waterproof Shielded Connectors
Termination and Assembly Instructions
The connectors are delivered with pre-assembed condition and the disassembly as shown No.1.
No. Illustration Solder termination fixture Operation
1
Plug disassembly
1
Insert the plug into securely held solder termination fixture as shown.
Fixture Part No. Applicable connector LF07BP-T01 LF07WBP-6S,6P,3S,3P LF10BP-T01 LF10WBP-4S,4P,12S,12P LF13BP-T01 LF13WBP-20S,20P,11S,11P
1
Plug
Locking collar Insertion direction Body / insulator assembly Backshell
2
2
Loosen the backshell turning it counter clockwise and remove it from the body/ insulator assembly.
1
Solder termination fixture Jack
Jack Disassembly
1
Insert the jack into the securely held solder termination fixture as shown.
Fixture Part No. Applicable connector LF07BJ-T01 LF07WBJ-6S,6P,3S,3P LF10BJ-T01 LF10WBJ-4S,4P,12S,12P LF13BJ-T01 LF13WBJ-20S,20P,11S,11P
Insertion direction
2
Body / insulator assembly Backshell
2
Loosen the backshell turning it counterclockwise.
2
1
Backshell
Connector Assembly
1
Apply a coating of Loctite 7649 (Manufactured by Henckel Japan, Ltd,) primer to the threaded sections of the backshell and the tightening collar. Completely dry the coated surfaces.
Threaded section
Threaded section
Note (1) Drying time at room temperature is approximately 30 to 70 seconds. (2) Ensure sufficient ventilation of the area at time of drying. (3) Take necessary steps to protect the coated surfaces from contamination.
Tightening collar
6
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF SeriesMiniature Waterproof Shielded Connectors
No.
Illustration
Operation
2
2
Backshell
2
Strain relief collar Tightening collar
Thread the tightening collar, strain relief collar, seal bushing and the backshell over the cable as illustrated.
Cable preparation end
Seal bushing
Cable
3
1
A
Cable outer jacket
Cable preparation
1
Strip the cable's outer jacket to the dimensions illustrated in the table 1.
Shielding mesh Table 1. Stripping Dimensions
Number of Conductors 3 6 4 12 11 20 A mm 8 to 9 13 to 14 14 to 15 22 to 23 (No.A to D) 23 to 24 (No.1 to 7) 23 to 24
Note (1) Exercise caution not to damage the shielding mesh. (2) Any damage to the cable's outer jacket may affect the waterproof performance of the assembled connector.
2
Shielding mesh Wires Cable outer jacket
2
Fold back the shielding mesh over the cable's outer jacket assuring that it is uniform on its diameter.
4 to 5mm Wires Cable outer jacket
Shielding mesh (Folded back)
3
B
Stripping dimensions Cable outer jacket Wires
3
Strip the wires to the dimensions illustrated in the Table 2.
Note When stripping the wires exercise caution not to damage it's insulation, folded over shielding mesh or cable's outer jacket.
Conductors Table 2. Stripping Dimensions
Number of Conductors 3 6 4 12 11 20 B mm 2.50.5 20.5 30.5 20.5 30.5 (No.A to D) 20.5 (No.1 to 7) 20.5
7
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF SeriesMiniature Waterproof Shielded Connectors
No.
Illustration
Operation
4
Soldering
1
Soldering conditions Soldering iron tip temperature: 35010c Soldering time: within 5 sec.
Note (1) Assure that the solder compound is sufficiently melted on the soldering iron tip. (2) When applying, make sure that the solder will flow correctly at all the contact surfaces between the conductor and the contact.
2
-1
Cmm
Wire
2
- 1 6, 12, 20, 11
Conductors
Insulator Contact Table 3 Number of Conductors Number of contacts mm
(1) Place a heat-shrink tubing (inside diameter of 1.1 mm min.) over every other wire. Perform the soldering of the contact and the (2) conductor, with the wire's insulation touching the contact as shown. After soldering, slide the heat shrink tubing (3) over the soldered joint and shrink it. The tubing should touch the insulator as shown.
Heat-shrink tubing
2
-2
Insulator Insulator wall
2
- 2 3, 4, 11
Conductors
Insulator
Contact Contact Insulator wall
Wire insulation
(1) Perform the soldering of the contact and the conductor, with the wire's insulation touching the contact as illustrated. (2) When soldering, to maintain the insulation between adjacent contacts. Make sure that the wire's insulation remains below the edge of the insulator's wall 0.5 mm min., as illustrated.
Wire insulation Solder 0.5 mm min. Cable outer jacket
3
3
After the soldering, keep a distance of between the contact end and the cable's outer jacket as illustrated.
Note Shielding mesh (Folded back) Table 4. Wire Dimensions Number of Conductors 3 6 4 12 11 20 mm 6 to 7 10 to 11 13 to 14 18 to 19 The distance of is required in order to assure correct assembly of the backshell.
8
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF SeriesMiniature Waterproof Shielded Connectors
No.
Illustration
Operation
5
1
Crimping of the Shielding Clamp
Solder termination fixture Body / insulator assembly
1
After completion of the soldering operations carefully remove (holding on the locking collar) the body/insulator assembly from the solder termination fixture.
Note Soldered joints Exercise caution not to damage or deform the solder joints.
2
Wires
Cable outer jacket Cable outer jacket 2 mm max. Copper tape
2
Wrap the folded over shielding mesh with 5 to 6 mm wide copper tape to assure that it will not become loose. Apply the copper tape so that the shielding mesh does not protrude from under it.
Shielding mesh
Note Copper tape 5 to 6mm After wrapping the copper tape, the tape should overlap itself by 2 mm max.
3
Cable outer jacket Ground clamp Copper tape 10.5mm Copper tape Cable outer jacket
3
Insert the "U" shaped shielding clamp over the copper tape as shown on the illustration. It is critical that the overlap of the copper tape is located inside the shielding clamp as shown on the illustration.
Note When the end of the copper tape wrapping is positioned at the open side of the ground fitting, the end portion of the copper tape wrapping will no longer be covered by the ground fitting when the ground fitting is crimped.
Wires Shielding mesh Overlap of the copper tape
Shielding clamp
4
Commercially available pliers E
4
Using commercially available pliers bend the open ends of the shielding clamp as illustrated, assuring that it stays in place. The dimension of E. between opposing edges of the shielding clamp is necessary to assure correct final crimp.
Table 5 Shell size Shielding clamp Overlap of the copper tape
9
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF SeriesMiniature Waterproof Shielded Connectors
No.
Illustration
Operation Crimping tool
5
5
Forming cavity
5
Both sides of the shielding clamp must be placed in the forming cavity of the tool (as shown on the illustration) and crimped over the cable by closing the tool completely.
Crimping tool Forming cavity HR10A-TC-02
5.3 7.0 7.9 9.1
Applicable cable diameter
Shielding clamp diameter after crimping
5mm --- 7.3mm 8.7mm
5.3mm to 5.5mm
5.3
7.0
---
7.9mm to 8.1mm 9.1mm to 9.3mm
LF-TC-01
6
1
,
2
Threaded section Backshell
Connector Assembly
1
Place the body/insulator assembly in the applicable solder termination fixture.
For plug assembly Fixture Part No. LF07BP-T01 LF10BP-T01 LF13BP-T01 For jack assembly Fixture Part No. LF07BJ-T01 LF10BJ-T01 LF13BJ-T01 Applicable connector LF07WBJ-6S,6P,3S,3P LF10WBJ-4S,4P,12S,12P LF13WBJ-20S,20P,11S,11P Applicable connector LF07WBP-6S,6P,3S,3P LF10WBP-4S,4P,12S,12P LF13WBP-20S,20P,11S,11P
Wrench width : D Table 6
Shell size Tightening torque Wrench width LF07 LF10 LF13
1N*m~1.5N*m 1N*m~1.5N*m 1.5N*m~2N*m 10mm 13mm 16mm
2
Coat the thread section of the body/insulator assembly with Loctite 271 compound (manufactured by Henckel Japan, Ltd.) or equivalent, tightening it with a torque specified in the table 6. It is critical that the cable itself will not turn or twist during this operation.
Note
3
,
4
3
Seal bushing Strain relief collar
Slide forward the seal bushing and insert it in the backshell until fully seated. Slide forward the strain relief collar and insert it in the backshell, making sure that the opposing protrusions fit inside the corresponding grooves, as shown on the illustration.
4
Groove
Protrusion Tightening collar
Note It is critical that the protrusions are inside the corresponding grooves.
5
Threaded section Tightening collar
5
Verify that the Locktite 7649 primer (or equivalent) on the threaded sections of the backshell and tightening collar are dry. Apply the Locktite 271 compound to the tightening collar's threaded section and attach it to the backshell.
10
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. LF SeriesMiniature Waterproof Shielded Connectors
No.
Illustration
Operation Tightening collar
6
6
6
Remove the connector from the solder termination fixture, holding it by the locking collar. Do not pull on the cable.
Wrench width
Shell size Tightening torque Wrench width LF07 LF10 LF13
0.8N*m~1N*m 0.7N*m~1N*m 1 N*m~1.5 N*m 10mm 13mm 16mm
1. To maintain the water/dust protection performance and the cable clamp force, use a cable that is within the range of applicable diameter. 2. Consult HRS representative when using different cables.
Cable Specifications (Reference)
No. of contact Material Conductor Size (mm) Construction Size (AWG) Sectional area Diameter (mm) Insulator Diameter (mm) Material Density Diameter (mm) Diameter (mm) O0.18 AWG #20 ------- O0.98 O1.5 (Standard) Soft copper wire 85% O3.6 O50.2 3 pos. Soft copper wire O0.26 AWG #16 1.25 O1.5 O2.1 (Standard) 0.3 Soft copper wire 80% O5.5 O7.30.2 4 pos. Soft copper wire O0.16 AWG #26 ------- O0.48 0.2 Soft copper wire 85% O3.4 O50.2 6 pos. Soft copper wire 12 pos. Soft copper wire O0.16 7 /O0.16 mm dia. AWG #26 0.14 O0.48 0.21 Soft copper wire 80% O4.2 O7.30.2 20 pos. Soft copper wire O0.16 7 /O0.16 mm dia. AWG #26 0.14 O0.48 O0.9 (Standard) 0.21 Soft copper wire 80% O5.1 O8.70.2 O0.26 11 pos. Soft copper wire Soft copper wire O0.16 26 /O0.26 mm dia. 7 /O0.16 mm dia. AWG #16 AWG #26 1.25 O1.5 0.3 0.14 O0.48 0.235 80% O6.7 O8.70.2
20 /O0.18 mm dia. 20 /O0.26 mm dia. 7 /O0.16 mm dia.
O0.88 (Standard) O0.9 (Standard)
O2.1 (Standard) O0.95 (Standard) Soft copper wire
Thickness (mm) 0.26
Jacket
Shield
11


▲Up To Search▲   

 
Price & Availability of LF07-WBR-11P

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X